Detail Kyoritsu KEW 2012R Digital Multimeter
Kyoritsu KEW 2012R Digital Multimeter
• Innovative Multhimeters with current measurements up to 120A AC/ DC
• Unique Open Jaw technology for AC/ DC current measurements
• Very compact and as reliable as a tradictional full size multimeter
Specifications
DC V: 600.0mV/ 6.000/ 60.00/ 600.0V ( Input impedance: approx. 10M© ) , ± 1.0% rdg± 3dgt
AC V: 6.000/ 60.00/ 600.0V ( Input impedance: approx.10M© ) , ± 1.5% rdg± 5dgt ( 45 ~ 400Hz)
DC A: 60.00/ 120.0A, ± 2.0% rdg± 8dgt ( 60A) , ± 2.0% rdg± 5dgt ( 120A)
AC A: 60.00/ 120.0A, ± 2.0% rdg± 5dgt ( 45 ~ 65Hz)
© :
600.0© / 6.000/ 60.00/ 600.0k© / 6.000/ 60.00M©
± 1.0% rdg± 5dgt ( 600© / 6/ 60/ 600k© )
± 2.0% rdg± 5dgt ( 6M© )
± 3.0% rdg± 5dgt ( 60M© )
Continuity buzzer: Buzzer sounds below 35± 25©
Diode test: 2V± 3.0% rdg± 5dgt Open-loop voltage: approx. 2.7V
Capacitance: 400.0nF/ 4.000/ 40.00µ F, ± 2.5% rdg± 10dgt
Frequency:
( AC A) : 100/ 400Hz, ± 0.2% rdg± 2dgt ( 100Hz) , ± 0.1% rdg± 1dgt ( 400Hz)
( DC A) : 100/ 1000Hz/ 10/ 100/ 300.0kHz, ± 0.2% rdg± 2dgt ( 100Hz) , ± 0.1% rdg± 1dgt ( 1000Hz/ 10/ 100/ 300.0kHz)
( Input sensitivity Current: more than 6A Voltage: more than 6V [ ~ 10kHz] / more than 20V [ 10k~ 300kHz] )
Conductor size: Ø 12mm max.
Withstand voltage: 3540V AC for 5 seconds
Applicable standards:
IEC 61010-1 CAT.III 300V, CAT.II 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326
Power source: R03 ( 1.5V) × 2
* Continuous measuring time:
DCV: approx. 150hours, ACA: approx. 25hours
( Auto power save: approx. 15 minutes)
Dimensions: 128( L) x92( W) x27( D) mm
Wiehgt: 220g approx. ( including batteries)
Accessories: R03 ( 1.5V) x2, instruction manual
Optional: 9107 ( Carrying case [ Soft] )
Tampilkan Lebih Banyak