Detail Fluke 120 Series Industrial ScopeMeter Handheld Oscilloscope
Fluke 120 Series Industrial ScopeMeter hand held oscilloscopes
The compact ScopeMeter 120 Series is the rugged solution for industrial troubleshooting and installation applications. It? s a truly integrated test tool, with oscilloscope, multimeter and ' paperless' recorder in one affordable, easy-to-use instrument. Find fast answers to problems in machinery, instrumentation, control and power systems.
ScopeMeter 120 Series : As simple as one-two-three
Dual-input 40 MHz or 20 MHz digital oscilloscope
Two 5, 000 counts true-RMS digital multimeters
Automatic measurements
A dual-input TrendPlot? recorder
Connect-and-View? trigger simplicity for hands-off operation
Shielded test leads for oscilloscope, voltage, resistance and continuity measurements
10: 1 Voltage Probe included with Fluke 124 and 125 for high frequency measurements
Up to 7 hours battery operation
600 V CAT III safety certified
Optically-isolated interface for PC connection
Rugged, compact case
Fluke 125 gives bus health and power measurements
In today? s complex systems, a meter measurement just doesn? t give enough detail to determine the cause of a fault. Signal anomalies, dropouts and glitches that might cause a machine to go down, are best displayed with an oscilloscope. The ScopeMeter 120 Series meet today? s need of simultaneously measuring and checking waveforms. The unique Connect-and-View? triggering automatically displays stable waveforms of virtually any signal. It really is as easy as one-two-three!
Specifications
1.Oscilloscope Bandwidth
Fluke 125: 40 MHz
Fluke 124: 40 MHz
Fluke 123: 20 MHz
2.Dual input True RMS Meter:
Vdc, Vac, Vac+ Vdc, Ohms, Continuity , Diode-test Current, C, F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset
3.TrendPlot Recording:
Automatic vertical scaling and time compression. Display the actual, MIN, MAX and AVG reading.
4.Cursors: Fluke 125/ 124: T, 1/ T, V, V, rise- and fall time
5.Real-time sample rate: 25 MS/ s
6.Equivalent sampling rate: up to 2.5 GS/ s ( 125, 124) or 1.25 GS/ s ( 123) .
7.Inputs and digitizers: 2
8.Timebase range
Fluke 125/ 124: 20 ns - 1 min/ div
Fluke 123: 10 ns - 1 min/ div
9.Input sensitivity: 5 mV - 500 V/ div
10.Trigger types: Connect-and-View? , Free Run, Single Shot, Edge, Video, External
11.Glitch capture: 40 ns
12.Scope measurements:
Automatic measurements: 26 ( all instruments) On top, Fluke 125 has additional measurement functions for Power ( W) , VA, VAR and Power Factor ( PF) for single phase and balanced-three-phase ( delta) power systems.
13.Harmonics mode:
Fluke 125 has capbility to analyze the harmonics contents of power signals. See below for details.
14.Maximum record length: 512 min/ max pts per input
15.Memory:
Fluke 125/ 124: 20 screens and setups
Fluke 123: 10 screens and setups
Additional Power measurement capabilities ( Fluke 125 only)
1.Measurement types: Watt, VA, VAR, Power Factor ( PF)
2.Power configuration: Single phase or balanced three-phase ( delta-configuration) mains supply
3.Voltage measurement: Channel A; using STL120, voltage probe or direct input
4.Current measurement: Channel B, using i400s ( included) or other compatible current clamp
5.Current Clamp or Shunt sensitivity: 0.1 / 1 / 10 / 100 / 1000 mV/ A, 10 mV/ mA and 400 mV/ A.
Harmonics Mode ( Fluke 125 only)
Converts waveform information into a harmonics display ( using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic
1.Analyzed waveform:
Voltage waveform( Ch.A) , Current wavefrom ( Ch.B) or Power ( Ch.A x Ch.B) , automatically generated.
2.Harmonics Frequency range:
DC up to 33rd harmonic ( for fundamental up to 60 Hz) ;
DC up to 24th harmonic ( for fundamental up to 400 Hz) .
3.Display:
Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental
4.Measurements: Relative amplitude of individual harmonics; THD in % r or % f.
Environmental Specifications
1.Operating Temperature: 0 C to 50 C
2.Storage Temperature: -20 C to + 60 C
3.Operating Altitude: 3, 000 m
Safety Specifications
1.Electrical Safety: 600V CAT III ( EN61010-1)
Mechanical & General Specifications
Size: 232 x 115 x 50 mm
Weight: 1.2 kg
Warranty: 3-years on main instrument, 1-year on accessories
Battery Life: 7 hrs using NiMH
RS232/ USB Interface: Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC
Tampilkan Lebih Banyak